BUSE=0, RSM=0, INCBA=0, HJACKCTL=0, ABT=0
Bus Control Register
INCBA | Include I3C Broadcast Address 0 (0): Do not include I3C broadcast address for private transfers 1 (1): Include I3C broadcast address for private transfers |
HJACKCTL | Hot-Join Acknowledge Control 0 (0): ACK the Hot-Join request 1 (1): NACK and send broadcast CCC to disable Hot-Join |
ABT | Abort 0 (0): I3C is running. 1 (1): I3C has aborted a transfer. |
RSM | Resume 0 (0): I3C is running. 1 (1): I3C is suspended (RW1C). |
BUSE | Bus Enable 0 (0): I3C bus operation is disabled. 1 (1): I3C bus operation is enabled. |